!Configure Rotators You can enable up to '''eight''' rotators, or disable. * '''Name:''' for rotator can have maximum 25 characters (not required). If set name as '''n/a''', this rotator is not shown in control section. * '''USB Vendor id:''' must have at 4 characters. * '''USB Product id:'''must have at 4 characters. * '''USB sn:''' must have at least 1 characters, and maximum 20 characters. * '''From Azimuth:''' must be number 0-450 * '''To Azimuth:''' must be number 0-450 * '''Custom GET command:''' available command send to rotator for get azimuth **default for K3NG arduino control 'C\r' * '''Custom SET command:''' available command send to rotator for set azimuth **default for K3NG arduino control 'C\rM#\r' ** Command format *** '''\n''' [Carriage return|https://en.wikipedia.org/wiki/Carriage_return] *** '''\r''' [Newline|https://en.wikipedia.org/wiki/Newline] *** '''#''' entered azimut number For finding id's and serial numbers USB device you can use a pop-up window [https://remoteqth.com/img/split.png] on top of page. This window print dmesg message from kernel of system, After plug usb device you see [https://remoteqth.com/img/wiki-dmesg.png] [https://remoteqth.com/img/wiki-s-rot.png] Every rotator also listen to an unique IP port: Rot1-8 is responsible port 91-98. *'''[How to set usb device SerialNumber]'''